2012

Table Of Contents
Remove Spurious Points Select this check box to ignore spurious points in
the input file.
When this check box is clear, the file reader extracts spurious points.
Point Intensity Specifies how points are extracted from the input file.
Select from the following options:
None - the points come through as white.
Raw Intensity - the points use the intensity values stored in the file.
Color-Mapped Intensity - the points use a spectrum of RGB colors.
Gamma Corrected Intensity - the points use gamma-corrected raw
intensity values stored in the file.
Gamma Correction Level Specifies a gamma correction value used to adjust
the normalized point intensity values obtained from the file, and results in
lighter or darker images depending on the setting.
A gamma correction value in the range between 0.1 and 0.99 adjusts the
weighting of intensity values at the lower end of the intensity range, so that
the image appears lighter.
A gamma correction level above 1.0 has the effect of darkening the image.
NOTE A gamma correction of 1 means no changes.
See also:
Z+F Scan File Reader (page 192)
File Exporters Node
Use the settings in this node to configure the file exporters required to export
native Autodesk Navisworks files directly from CAD applications.
TIP If you want to restore the default values, click the Defaults button.
DWG Page
Use this page to adjust the options for the DWG file exporter.
Convert Entity Handles Select this check box to convert entity handles, and
attach them to object properties in Autodesk Navisworks.
Options Editor Dialog Box | 813