2010
Table Of Contents
- Contents
- Welcome to Autodesk Navisworks Manage 2010
- Installation
- Quick Start to Stand-Alone Installation
- Prepare for Installation
- Install and Run Autodesk Navisworks Manage 2010
- Move to Autodesk Navisworks from a Previous Release
- Install Autodesk Navisworks for Multiple Users
- Quick Start to Network Administration and Deployment
- Set Up a Deployment
- Installation Troubleshooting
- General Installation Issues
- How can I check my graphics card driver to see if it needs to be updated?
- When performing a Typical installation, what gets installed?
- Why should I specify the Project Folder and Site Folder?
- How do I share the Autodesk Navisworks settings on a site and project basis?
- Where are my product manuals?
- How do I register and activate Autodesk Navisworks?
- Deployment Issues
- Licensing Issues
- Networking Issues
- Uninstall and Maintenance Issues
- When adding or removing features, how can I tell what features get installed by default?
- Is it possible to change the installation folder when adding or removing features?
- When should I reinstall the product instead of a repair?
- Do I need my original disk to reinstall my software?
- When I uninstall my software, what files are left on my system?
- General Installation Issues
- Quick Start to Stand-Alone Installation
- Quick Start
- Get a Whole-Project View
- Work with Files
- Native File Formats
- Compatible CAD Applications
- Use File Readers
- 3DS File Reader
- ASCII Laser Scan File Reader
- Bentley AutoPLANT File Reader
- CIS2 File Reader
- DWG/DXF/SAT File Reader
- DWF File Reader
- DGN File Reader
- Faro Scan File Reader
- IFC File Reader
- IGES File Reader
- Inventor File Reader
- JTOpen File Reader
- Leica Scan File Reader
- MAN File Reader
- PDS File Reader
- Riegl Scan File Reader
- RVM File Reader
- SketchUp SKP File Reader
- STEP File Reader
- STL File Reader
- VRML File Reader
- Z+F Scan File Reader
- Use File Exporters
- Manage Files
- Explore Your Model
- Control Model Appearance and Render Quality
- Review Your Model
- Use Viewpoints and Sectioning Modes
- Record and Play Animations
- Work Within a Team
- Share Data
- Work with Files
- Animate Objects
- Create Photorealistic Visualizations
- Simulate Construction Scheduling
- Locate and Manage Interferences
- Autodesk Navisworks Reference
- File Options Dialog Box
- File Units and Transform Dialog Box
- New Link Dialog Box
- Edit Link Dialog Box
- Edit Viewpoint Dialog Box
- Options Editor
- Default Collision Dialog Box
- Collision Dialog Box
- Convert Object Properties Dialog Box
- Culling Options Dialog Box
- Customize Dialog Box
- Customize Keyboard Dialog Box
- Edit Key Frame Dialog Box
- Publish Dialog Box
- Background Settings Dialog Box
- QTVR Object Movie Settings Dialog Box
- Export Rendered Image Dialog Box
- Image Export Dialog Box
- Animation Export Dialog Box
- Glossary
- Index
Notification Icon
Notification icon indicates whether any new information is available. Balloon notifications appear over this icon
whenever new Communication Center content is available. You can right-click this icon to turn off the
notifications, or to customize the Communication Center options.
Pencil Progress Bar
The progress bar under the left hand icon (pencil) indicates how much of the current view is drawn, that is how
much drop-out there is in the current viewpoint. When the progress bar is at 100%, the scene is completely
drawn, with no drop-out. The icon changes color when a redraw is in progress. Whilst the scene is being drawn,
the pencil will change to yellow. If there is too much data to handle and your machine cannot process this
quickly enough for Autodesk Navisworks, then the pencil changes to red, indicating a bottleneck.
Disk Progress Bar
The progress bar under the central icon (disk) indicates how much of the current model is loaded from disk, that
is how much is loaded into memory. When the progress bar is at 100%, the entire model, including geometry
and property information, is loaded into memory. The icon changes color when a file load is in progress. Whilst
data is being read, the disk changes to yellow. If there is too much data to handle and your machine cannot
process this quickly enough for Autodesk Navisworks, then the disk changes to red, indicating a bottleneck.
Web Server Progress Bar
The progress bar under the right hand icon (web server) indicates how much of the current model is downloaded,
that is how much has been downloaded from a web server. When the progress bar is at 100%, the entire model
has been downloaded. The icon changes color when a file load is in progress. Whilst data is being downloaded,
the web server changes to yellow. If there is too much data to handle and your machine cannot process this
quickly enough for Autodesk Navisworks, then the web server changes to red, indicating a bottleneck.
Memory Bar
The field to the right of the icons reports the amount of memory currently being used by Autodesk Navisworks.
This is reported in Megabytes (MB).
Undo/Redo Commands
You can undo or redo your actions in Autodesk Navisworks.
The default settings are adequate for regular Autodesk Navisworks usage, but you can
adjust the amount of space
allocated to the undo/redo buffer, if necessary.
The Edit ➤ Undo and Edit ➤ Redo menu items state what type of action you can undo/redo.
To undo an action
■ Click Edit ➤ Undo on the Menu bar.
Command entry: CTRL + Z
Toolbar: Standard ➤ Undo
To redo an action
■ Click Edit ➤ Redo on the Menu bar.
Command entry: CTRL+Y
Toolbar: Standard ➤ Redo
72 | Chapter 4 Quick Start