5.0
2. Enter a new name for your rule.
3. From the Rule Templates list, choose a template to customize. The following templates are built in:
• Insulation Thickness. This rule is to be used with a Clearance test and will ignore any items
found clashing where the clearance is greater than the insulation thickness.
If you have a pipe requiring a specific thickness of insulation, then you may want to carry out a
clearance test on that pipe, setting the clearance tolerance to the required insulation thickness.
This would identify any areas where there is not enough clearance around the pipe to install the
insulation.
If you have various pipes, all requiring different thicknesses of insulation then rather than setting
up a seperate clearance test for each thickness, you can set up one test with the greatest
necessary tolerance, i.e. assume all pipes require the maximum thickness of insulation. This rule
can then be applied to ignore any clashes that are falsely identified, as their actual insulation
Clash Rules