2010
Table Of Contents
- Contents
- Part 1 Tubes and Pipes
- 1 Get Started with Tube & Pipe
- 2 Route Basics
- 3 Set Styles
- 4 Create Rigid Routes and Runs
- Workflow for Rigid Routes
- Create Auto Route Regions
- Manually Create Parametric Regions
- Automatically Dimension Route Sketches
- Create Segments With Precise Values
- Define Parallel and Perpendicular Segments
- Snap Route Points to Existing Geometry
- Place Constraints On Route Sketches
- Create Bends Between Existing Pipe Segments
- Create Pipe Routes With Custom Bends
- Create Bent Tube Routes
- Realign 3D Orthogonal Route Tool
- Control Dimension Visibility
- Populated Routes
- 5 Create and Edit Flexible Hose Routes
- 6 Edit Rigid Routes and Runs
- 7 Use Content Center Libraries
- 8 Author and Publish
- 9 Document Routes and Runs
- Part 2 Cable and Harness
- 10 Get Started with Cable and Harness
- 11 Work With Harness Assemblies
- 12 Use the Cable and Harness Library
- 13 Work with Wires and Cables
- 14 Work with Segments
- 15 Route Wires and Cables
- 16 Work with Splices
- 17 Work with Ribbon Cables
- 18 Generate Reports
- 19 Work With Nailboards and Drawings
- Part 3 IDF Translator
- Index
The placed fitting to restore must be within the tube or pipe segment or it
cannot be placed at the free terminal of the run.
Restore a default fitting
1 Activate the AirSystem1:1 run.
2 Right-click the placed cross and select Restore Fitting.
The placed fitting changes to a coupling fitting at the same position.
Replace Existing Fittings
You can replace one occurrence of a selected fitting instance with a new fitting
instance from the Content Center or all occurrences at once. The replacement
fittings can be inserted at previously defined route points.
Replaced fittings use the route information of the previous part. Orientation
and position can be adjusted if the part type and connection information
allows.
In this exercise, you place a tee from the Content Center to replace the
coupling you just restored from the placed cross. In addition, you can also
place a non-library replacement fitting using the Place Fitting tool.
Replace existing fittings with library fittings
1 Activate the AirSystem1:1 run.
136 | Chapter 6 Edit Rigid Routes and Runs