2010

Table Of Contents
must also be appropriate for the drop point selected. For example, elbows may
not be dropped on straight segments.
For a placed fitting or a routed fitting for which you have changed the fitting
diameter, you can:
Change its orientation, as well as connection point.
Change the fitting route point position on straight rigid segments.
Replace existing fittings.
Restore original fittings, typically elbows and couplings.
Delete placed fittings and default couplings. You cannot delete the default
directional fittings.
Place Fittings in the Active Project Workspace
Fittings from the active project workspace are added to the design using the
Place Fitting tool on the Pipe Run tab.
NOTE You cannot place conduit parts using this tool.
Place a fitting from your project workspace
1 Activate the pipe run to receive the fitting.
2
On the ribbon, click Pipe Run tab Route panel Place
Fitting.
3 In the Open dialog box, browse to and select the component to place,
and then click Open.
The selected component is placed in the graphics window, attached to
the cursor.
4 Click a point of your choice for insertion.
To insert an elbow, select a direction change route point.
To insert other types of components, select any point along an existing
run segment.
Place Fittings in the Active Project Workspace | 131