2.0

Table Of Contents
Editing Conceptual Plan Pipe Runs Using the Pipe Run Editor
679
Pipe Runs in Plan View (continued)
Column Headings Description
Surface On/Off
This column contains the runoff file on/off value, with On represented by 1 and Off
represented by 0 (zero). For information about the Runoff option, refer to the section,
Runoff, later in this command description.
Thickness In
This column contains the structure wall thickness in value.
Thickness Out
This column contains the structure wall thickness out value.
Wet Area
This column contains the pipe cross section wetted area value based on the design flow
calculation. This value is determined based on the current pipe configuration and flow
calculation formula. You can make your own pipe cross section wetted area calculations, if
necessary. Place your cursor in the Wet Area column and click Edit to open the appropriate
Pipe Calculator dialog box.
Wet Perim.
This column contains the pipe cross section wetted perimeter value based on the design
flow calculation. This value is determined based on the current pipe configuration and flow
calculation formula. You can make your own pipe cross section wetted perimeter
calculations, if necessary. Place your cursor in the Wet Perim column and click Edit to open
the appropriate Pipe Calculator dialog box.
Copying or Clearing the Fields and Columns in
the Pipe Run Editor
To copy or clear the fields and columns in the pipe run editor
1 From the Pipes menu, choose Conceptual Plan ä Edit Data.
2 Do one of the following:
n
Select the run with your pointing device.
n
Press ENTER to open the Defined Runs dialog box, select the run, and then
click OK.
All pipe runs are stored in a single Pipeworks database called pipeworks.mdb.
After you select a run, the Pipeworks database is automatically searched for the
run with the specified name.
NOTE
The .mdb file is a Microsoft Access file, so you can view the .mdb file using
Microsoft Access.
After the pipe run is found, the Pipes Run Editor dialog box is displayed with
the selected pipe run data. For more information, see Changing the Pipe Run
Editor Settings in this chapter.