2.0

Table Of Contents
Chapter 6 Working with Pipes
666
10 Click the Calculate button if Hydraulic Calculation is set to None in the Pipes 
Editor Settings dialog box.
The program automatically re-calculates the pipe design.
Pipes Run Editor Controls
The following are controls in the Pipes Run Editor dialog box:
n
Click the Save button to save all edits you made to the current run in the
Pipes Run Editor.
n
Click the Settings button to display the Pipes  Editor Settings dialog box.
n
Click the Edit button after you place the cursor in a field to display
information about a particular pipe run.
n
Click the Tools button after you place the cursor in a field to display the Run
Editor Toolbox dialog box. You can copy or clear the contents of a cell or
column in the Pipes Run Editor.
n
Click the Runoff button after you select a row to display the Runoff dialog
box, where you can specify the runoff flow into the current pipe.
n
Click the Messages button to display the Messages dialog box. If design
requirements have not been met, for example, maximum and minimum
slopes have been exceeded, or maximum cover depth has been exceeded,
then the default text editor displays the discrepancies.
NOTE
Settings pertain to those set in the Pipes  Editor Settings dialog box and the
Range Check Settings dialog box.
Changing the Precision Settings
To change the precision settings
1 From the Pipes menu, choose Conceptual Plan
ä
Edit Data.
The following prompt is displayed:
Pick run:
2 Do one of the following to select a run:
n
Select the run with your pointing device.
n
Press ENTER to open the Defined Runs dialog box.
Under Selection, select the defined run, and then click OK.
All pipe runs are stored in a single Pipeworks database called pipeworks.mdb.
After you select a run, the Pipeworks database is automatically searched for the
run with the specified name.
NOTE
The .mdb file is a Microsoft Access file, so you can view the .mdb file using
Microsoft Access.
After the pipe run is found, the Pipes Run Editor dialog box is displayed with
the selected pipe run data. For more information, see Changing the Pipe Run
Editor Settings in this chapter.