2.0

Table Of Contents
Chapter 6 Working with Pipes
662
sewer district. Where the run does not meet those requirements, you need to
edit the run before continuing with the design of your sanitary sewer system.
The following illustration shows conceptual pipe run in plan view:
Conceptual pipe run in plan view
Editing Conceptual Pipe Runs in Plan View
To edit conceptual pipe runs in plan view
1
From the Pipes menu, choose Conceptual Plan รค Edit Graphical.
The following prompt is displayed:
Select run to edit:
2
Select a point on the pipe run near the node to be edited.
An X, drawn with temporary vectors, marks the node nearest to the selection
point. The following options are now available:
Next/Prev /DElete /DBase /Undo /Save /Add /Move /eXit <eXit>:
If an option that requires a rim elevation is selected, such as Move, then a
dialog box is displayed prompting you to turn on the current surface.
3
Type any of the following:
n
N for the Next option, to advance the X designating the current node in the
pipe run to the next available node.
n
P for the Prev option, to move the X designating the current node in the
pipe run back to the previous node.
n
D for the DElete option, to remove the current node in the pipe run back to
the previous node.
n
DB for the DBase option, to display the Edit Run Node dialog box,
depending on whether a pipe or node is current. You can change values in
this dialog box by highlighting the appropriate field, then entering the
changes in the Edit text box. This editor is dynamically linked to the
drawing. If you make changes in the Edit Table dialog box, then clicking OK
results in the pipe run being redrawn to reflect those changes.
n
U for the Undo option, to reverse any previous action taken in the pipe run
drawing process, except for changes made to the node data in the Edit Table
dialog box with the DBase option.
n
S for the Save option, to save the pipe run data to the database. The Run
Alignment Association dialog box is displayed. This dialog box lists the Run
and the Current Alignment with which the pipe run is associated. There are