2.0

Table Of Contents
Chapter 6 Working with Pipes
630
4 Click OK to accept the plan exaggeration factor(s) and exit the Nodes and
Pipes  Plan Exaggeration Factor dialog box.
5 Click OK to exit the Pipes Settings Editor dialog box.
Changing the Pipe Run Editor Settings from the
Settings Dialog Box
Use the Pipes - Run Editor Settings dialog box to establish settings for flow
calculations, pipe roughness formula, pipe capacity, pipe length types, and
hydraulic and energy grade line calculations.
To change the pipe run editor settings
1 From the Pipes menu, choose Settings ä Edit to display the Pipes Settings Editor
dialog box.
2 In the Editors section, click the Run Editor button to display the Pipes - Run
Editor Settings dialog box.
The Calculate section has three options: Upstream to downstream, Downstream
to upstream, and None.
3 Do one of the following:
n
Select Upstream to downstream to specify that pipe calculations are made
from upstream to downstream.
n
Select Downstream to upstream to specify that pipe calculations are made
from downstream to upstream.
n
Select None to turn off pipe calculations.