2.0

Table Of Contents
Displaying and Reporting the Cross Section Control Values
377
NOTE
The values in this dialog box are for display only; you cannot edit them.
2 Click the Next, Previous, and Station buttons to move between stations.
When you click Station, the Station Entry dialog box is displayed. Type the
value for the station you want to see, and then click OK.
3 Click OK to exit the command.
Displaying the Control Errors
To display any error messages that have been generated while processing
sections
1 From the Cross Sections menu, choose Design Control รค Display Control Errors
to display the Control Processing Errors dialog box.
2 Use the scroll bar to the right of the error messages to move through the list of
messages.
The following is a list of all possible error messages:
Warning: Station: {Station} Left slope pinned to ROW
Warning: Station: {Station} Left slope pinned to end
Warning: Station: {Station} Left slope pin override used
Warning: Station: {Station} Right slope pinned to ROW
Warning: Station: {Station} Right slope pinned to end
Warning: Station: {Station} Right slope pin override used
Warning: Station: {Station} Template larger than cross section
Warning: Station: {Station} No vertical exists
Warning: Station: {Station} No valid template assigned
Station: {Station} No cross section defined
Station: {Station} No crown or left EOP found, super set to 0.
Station: {Station} No crown or right EOP found super set to 0.
Template {Template} not found in template subdirectory.
Datum surface <{Datum}>, not found.
Top surface <{Top Surface}>, not found.