2012

Table Of Contents
Controls the shape of lofted solids and surfaces.
The setting is stored as a bitcode using the sum of the following values:
No twist (minimizes the twist between cross sections)1
Align direction (aligns the start to end direction of each
cross section curve)
2
Simplify (produces simple solids and surfaces, such as a
cylinder or plane, instead of spline solids and surfaces)
4
Close (closes the surface or solid between the first and the
last cross sections)
8
LOGEXPBRIGHTNESS
Quick Reference
See also:
Standard and Photometric Lighting Workflow
RealType:
DrawingSaved in:
65.0Initial value:
Controls the brightness level of the viewport when using photometric lighting.
Controls the brightness level of the viweport when photometric lighting is
enabled (
LIGHTINGUNITS on page 2402 system variable is set to 1 or 2). Valid
range is from 0.0 to 200.0. The brightness level in standard lighting can be
controlled by the LINEARBRIGHTNESS on page 2405 systems variable.
LOGEXPCONTRAST
Quick Reference
See also:
Standard and Photometric Lighting Workflow
LOGEXPBRIGHTNESS | 2411