2011

Table Of Contents
See also:
Add Geometric Tolerances on page 1513
To specify methods for lateral tolerances
1 Click Home tab Annotation panel Dimension Style.
2 In the Dimension Style Manager, select the style you want to change.
Click Modify.
3 In the Modify Dimension Style dialog box, Tolerances tab, under
Tolerance Format, select a method from the Method list, and then do
one of the following:
If you select Limits, enter upper and lower tolerance deviation in the
Upper Value and Lower Value boxes.
If you select Symmetrical tolerances, Lower Value is not available,
because you need only one tolerance value.
If you select Basic, enter a value in Offset from Dim Line (on the Text
tab) to represent the gap between the text and its enclosing box.
4 Click OK.
5 Click Close to exit the Dimension Style Manager.
To align and suppress zeros in tolerance values
1 Click Home tab Annotation panel Dimension Style.
2 In the Dimension Style Manager, select the style you want to change.
Click Modify.
3 In the Modify Dimension Style dialog box, Tolerances tab, under
Tolerance Format, select the alignment from the Vertical Position list.
4 To suppress zeros in primary or alternate units, under Zero Suppression,
select Leading to suppress leading zeros. Select Trailing to suppress trailing
zeros.
5 Click OK.
6 Click Close to exit the Dimension Style Manager.
1458 | Chapter 31 Dimensions and Tolerances