Controls the contrast level of the viewport when photometric lighting is
enabled (
LIGHTINGUNITS (page 1391) system variable is set to 1 or 2). Valid
range is from 0.0 to 100.0. The contrast level in standard lighting can be
controlled by the LINEARCONTRAST (page 1394) systems variable.
See also:
Standard and Photometric Lighting Workflow
LOGEXPDAYLIGHT
Controls if the exterior daylight flag is enabled when using photometric
lighting.
IntegerType:
DrawingSaved in:
2Initial value:
When this system variable is off, exterior daylight is turned off when
photometric lighting is enabled (
LIGHTINGUNITS (page 1391) system variable
is set to 1 or 2). When on, the exposure control algorithm in the rendering
acts as if there is an extremely bright light source in the scene. Therefore, the
default setting of Auto is tied directly to the sun setting. Under special
circumstances, it may be desirable to manually set this variable due to
extremely bright artificial light sources or, conversely, due to a sun-lit scene
that it is illuminated only by a small amount of directly visible sunlight.
Off0
On1
Auto, current sun status is used2
See also:
Standard and Photometric Lighting Workflow
LOGEXPMIDTONES
Controls the mid tones level of the viewport when using photometric lighting.