2013

Table Of Contents
User-settingsSaved in:
1Initial value:
This system variable also affects whether the new layer notification is displayed
or not.
Disables the evaluation and notification of new layers0
Enables the evaluation of new layers on LAYEREVAL settings in DWG
file
1
NOTE LAYEREVALCTL overrides the LAYEREVAL (page 1384) and LAYERNOTIFY (page
1386) setvars when LAYEREVALCTL = 0. It acts like a global off (but not a global on).
There is no effect even if LAYEREVALCTL is turned on if LAYERNOTIFY = 0 or
LAYEREVAL = 0. LAYEREVALCTL must be set to 1 for LAYERNOTIFY and LAYEREVAL
to function correctly.
See also:
LAYEREVAL (page 1384)
LAYERNOTIFY (page 1386)
LAYERFILTERALERT
Deletes excessive dynamic layer group filters to improve performance.
IntegerType:
RegistrySaved in:
2Initial value:
When a drawing has 100 or more dynamic layer group filters, and the number
of filters exceeds the number of layers, LAYERFILTERALERT provides a method
for deleting filters to improve performance.
Off0
When the Layers palette is opened, deletes all dynamic layer group
filters; no message is displayed
1
When the Layers palette is opened, displays a message that states
the problem, recommends deleting all dynamic layer group filters,
2
L System Variables | 1385