2011

Table Of Contents
Enter f to specify the perceived power in a luminous flux value.
Enter Flux (Lm) <18849.5556>:
If you enter i, you can specify the intensity of the light based on an illuminance
value.
Enter Illuminance ("Lx"|"Fc") or enter an option [Distance] <1500.0000>:
The illuminance value can be specified in either lux or foot-candles. Enter d
to specify a distance to use to calculate illuminance.
Enter Distance <1.0000>:
Color Enter color name or enter an option [?/Kelvin] <D65White>:
Specify the color of the light based on a color name or a Kelvin temperature.
Enter ? to display a list of color names.
Enter color name(s) to list <*>:
Enter a text string using wild card characters to display a partial listing of color
names, or an asterisk (*) to display all the possible choices.
If you enter k, you can specify the color of the light based on a Kelvin
temperature value.
Enter Kelvin temperature <3600.0000>:
Exit Exits the command option.
Shadow
Makes the light cast shadows.
Enter shadow settings [Off/Sharp/soFtmapped/softsAmpled] <Sharp>:
Off Turns off display and calculation of shadows for the light. Turning shadows
off increases performance.
Sharp Displays shadows with sharp edges. Use this option to increase
performance.
Soft Mapped Displays realistic shadows with soft edges.
Enter map size [64/128/256/512/1024/2048/4096] <256>:
Specifies the amount of memory to use to calculate the shadow map.
Enter softness (1-10) <1>:
Specifies the softness to use to calculate the shadow map.
Soft Sampled Displays realistic shadows with softer shadows (penumbra)
based on extended light sources.
Enter an option to change [Shape/sAmples/Visible/eXit]<eXit> :
POINTLIGHT | 817