a top (HW01_#), middle (HW02_#B), and bottom (HW02_#) symbol. The #
indicates whether the connecting lines should cross or not. A 1 results in
straight connecting lines, and a 2 results in crossing connecting lines.
You can create you own custom top and bottom shield symbols by copying
the existing symbols and adding a suffix to the symbol names after the _#.
For example, a new top shield symbol might be called HW01_1U, and the
corresponding bottom symbol, HW02_1U. Modify the symbols to meet your
needs. In the
icon menu on page 1239 add a new command option calling
wd_cblshld_bld 1P.
NOTE The same middle shield symbol can be used for all types.
Wire Gaps
Manipulate wire gaps
Manipulate wire gaps
Insert wire gaps
When a new wire crosses another, a gap/loop is inserted automatically. Under
some conditions, it is necessary to add a gap/loop manually at the point of
two crossing wires.
1 Click Schematic tab Insert Wires/Wire Numbers panel Insert
Wires drop-down Gap.
956 | Chapter 12 Wire/Wire Number Tools