2011

Table Of Contents
Distance from channel line to the origin; repeated for each
channel line.
CHANNEL
Distance from origin to channel end for each channel.CHANNEL_END
Length of rail to shift from one piece of rail to the next to
make sure last piece is not less than the minimum length.
MIN_SHIFT
Name of AutoCAD block for the drill hole.NCHOLE
Allow standoff brackets, Yes or No. If No, then the button
is disabled on the dialog. If Yes, the button is enabled and
you can select standoff brackets.
BRKT
Name of AutoCAD block for standoff bracket.BRKT_NAME
Manufacturer for standoff bracket. Added as Multi-BOM
on the created Din Rail block.
BRKT_MFG
Catalog number for standoff bracket. Added as Multi-BOM
on the created Din Rail block.
BRKT_CAT
Assembly code for standoff bracket. Added as Multi-BOM
on the created Din Rail block.
BRKT_ASMB
Name used to tie into the catalog lookup table. Values are
either DIN or WW based on whether the spreadsheet record
CATALOG_TABLE
is a din or wire way. This determines whether the DIN or
WW table (of the default_cat.mdb) displays when you click
Catalog Lookup on the Panel Layout - Component In-
sert/Edit dialog box.
Parametric building of wire ways
You can create generic wire way records in the spreadsheet (wddinrl.xls) for
parametric building of wire ways. To do so, add the following records in the
spreadsheet:
MFG = PANDUIT
CAT = Generic
DESC = Wire duct, 3.25"x3.11" tall, slotted
Overview of DIN Rails | 851