2011

Table Of Contents
3 Right-click to end the selection and apply the command.
Exclude contacts when cross-referencing
You can exclude the contact from being included in any AutoCAD Electrical
cross-reference text annotation.
1 Enter ATTEDIT at the command line.
2 Select the contact that you want to exclude from cross-referencing.
3 Change the CONTACT attribute value to NULL.
4 Click OK.
NOTE Run the Cross-reference command to update the cross-referencing on the
parent symbol.
Check coil/contact count
Using the
Cross-Reference Check on page 813 tool, AutoCAD Electrical first
extracts a complete list of components from the project drawing set. Then it
prompts you to select a component to check. AutoCAD Electrical reads the
tag of the component, finds all associated child components, and lists them
in a dialog box. It also displays the assigned catalog number of the parent (if
one exists). You can do a catalog check to see if the description of the item
indicates that the quantity of contacts can be accommodated.
Component reference listing
The Cross-Reference Check tool displays all associated and parent components
to the selected component.
Ribbon: Schematic tab Edit Components panel Modify Component
Cross-Reference drop-down Cross-Reference Check.
Toolbar: Cross-Reference
Menu: Components Cross-Reference Cross-Reference Check
Command entry: AEXREFCHECK
Check coil/contact count | 813