2011

Table Of Contents
3 (Optional) Type Ctrl + Z to undo the contact swap if you selected the
wrong component.
Existing attribute text is preserved on the flipped contact. If the maximum
contact counts are carried by the parent symbol, the maximum counts
are checked so that they are not exceeded by the flip.
Component Cross-References
Cross-Referencing
Cross-referencing is based on collecting and annotating groups of components
that carry the same TAG text string value (for example, 101CR). Components
do not have to be of the same family to be cross-referenced, but they must
have the same TAG1/TAG2/TAG_*/TAG attribute values.
Cross-reference data is annotated on to attributes XREFNO and XREFNC for
N.O and N.C. references respectively. Alternately, if attribute XREF is present,
both N.O. and N.C. references are combined into a single cross-reference text
string.
The AutoCAD Electrical Component Cross-reference tool creates two text
reports in the process of annotating components with cross-reference
information. The Cross-reference report gives a listing of each component
and quantity and locations of child contacts. The Exception/Error report lists
the exceptions AutoCAD Electrical found as it processed the drawing or drawing
set. Exceptions include child contact with no parent and parent relay coil
with no child contacts found.
Cross-Reference
1 Click Schematic tab Edit Components panel Modify Component
Cross-Reference drop-down Component Cross-Reference.
2 Select to process:
Project - select from a list of project drawings to process.
Active drawing (all) - process all components on the active drawing.
Active drawing (pick) - select components to process.
Component Cross-References | 809