2011

Table Of Contents
NOTE When you add a record you must indicate if the component or circuit is
Schematic or Panel and you need to indicate if it should be inserted as a block or
exploded upon insert (as you would for a circuit). Then, at a minimum, you need
to define the block name and either the catalog number or description.
Select Schematic or Panel Device
Specifies if the component (or circuit) is Schematic or Panel.
Single block or explode on insert
Specifies if it should be inserted as a block or exploded upon insert (as you
would for a circuit).
Minimum of Block Name and either Description or Catalog
Block/Assembly/Circuit: The Block value can be a symbol name or AutoLISP
expression. If the footprint block is not in an AutoCAD search path or an
AutoCAD Electrical search path, include the part of the path that needs
to be appended to one of these search paths (or enter the full path to the
footprint block). Use Browse to locate the block name.
Description: Specifies the optional comment for the footprint record. This
is for reference in this file only. It does not get extracted into any AutoCAD
Electrical report
Catalog: (not used for exploded inserts) The Catalog value may contain
wildcards. Wildcard characters include:
* = match any characters
? = match any single character
# = match any single numeric digit
@ = match any single alphabetic character
NOTE If the catalog number actually has a character in it like #, then precede
it with the ` char, example "F120#10" would be "F120`#10"
Optional Values
(These options are not available for exploded inserts) Options for specifying
the manufacturer code, assembly code, and text values. If the catalog
information includes an ASSYCODE value, include it in the record to ensure
a complete match. If the same footprint is used no matter what the ASSYCODE
value is (ex: different combinations of contact blocks on a base relay) then
use " * " wildcard character for the ASSYCODE value in the record.
Insert from catalog lists | 779