UI_VALMain Disconnecting Means Option
6Disconnect switch and fuses (time-delay)
8Fuses
10Fuses (time-delay)
12Circuit Breaker
14Circuit Breaker-thermal/inverse-time
16Circuit Breaker-magnetic/instantaneous
0None
For example, the one-line circuit used the Disconnect switch and fuses
(time-delay) option with a UI_VAL of 6. When the 3-phase circuit references
this one-line circuit, the disconnecting means option with a UI_VAL of 6
becomes the default. If a matching UI_VAL is not found for a particular marker
block CODE value, the default as defined by the X in the UI_DEF column
is used.
Reference an existing circuit
1 Click Schematic tab Insert Components panel Circuit Builder
drop-down Circuit Builder.
2 Select the circuit from the Circuits list or select History to display the list
of previously configured circuits.
3 (Optional) Enter a Circuit Scale. This value sets an insertion scale value
for the circuit template.
4 (Optional) Enter a Component Scale. This value sets an insertion scale
value for the individual components inserted while building the circuit.
5 (Optional) Enter a Horizontal Rung Spacing.
6 (Optional) Enter a Vertical Rung Spacing.
7 Select Reference Existing Circuit.
Reference an existing circuit | 723