values. The template marker code maps the values from the components
in the existing circuit to the components in the new circuit.
VIA_WD_CB_CIRCPARAMS - comma-delimited list that includes data
returned from any Select Motor or Select Load dialog box.
VIA_WD_CB_CIRCPARAMS2 - list of motor or load wire size assignments.
VIA_WD_CB_CIRCSELECT - comma-delimited list that includes the template
name, spreadsheet file name, and sheet name.
NOTE If there are no existing circuits in the active project that carry the
VIA_WD_CB_CIRCCODE xdata, the Reference Existing Circuit option is disabled.
Referencing an existing circuit depends on:
Marker block CODE values
UI_VAL values from the circuit builder spreadsheet
Marker Block CODE values
Referencing an existing circuit depends on finding matching marker block
CODE values used in both the referenced circuit and the circuit being inserted
or configured. For example, a referenced one-line circuit used marker block
code Q001 to trigger insertion of the main disconnecting means. The new
three-line schematic circuit being inserted needs to have a marker block code
Q001 marking where the three-pole disconnecting means is to be inserted.
The result is that component values from the referenced circuit are applied
to components in the new circuit when the
marker block on page 659 codes
match.
Spreadsheet UI_VAL values
The default circuit element options are controlled by both the CODE value
and the UI_VAL from the
circuit codes sheet on page 655 of the circuit builder
spreadsheet. There may be multiple options for a particular CODE value. For
example, the main disconnecting means may have the following options,
each with a UI_VAL assigned.
UI_VALMain Disconnecting Means Option
2Disconnect switch - non-fused
4Disconnect switch and fuses
722 | Chapter 9 Circuits