On the Select Circuit dialog box, select a circuit, click Configure, enter the
Motor Setup parameters, and then select the Wire Setup Browse button.
Load
Sets the voltage for the wire conductor.
Voltage
Sets the phase of the electrical power.
Phase
Sets the full load amps carried by the wire conductors.
FLA
Sets the value that is multiplied by the FLA value to
calculate the maximum load for the wire conductors.
FLA multiplier
Sets the amp value of any additional loads to be com-
bined with the main motor or load and fed from this
Other
common branch circuit set of conductors. This value
is added to the product of the FLA times FLA multiplier.
Displays the calculated maximum load for the conduct-
ors. It is based on the FLA (Other) value added to the
product of the FLA times the FLA multiplier value.
Maximum load
NOTE Controls are disabled if the values are predefined on the Circuit
Configuration dialog.
Wire
Sets the wire standard. Directs Circuit Builder to use
specific tables from the electrical standards database
Size standard
for that wire size standard. The available values are ex-
tracted from the electrical standards database table
names.