Filter the listing based on phase. Select <All> from the list to turn
off filtering for this field.
Phase
Select a load to pass the values back to the Circuit Configuration
dialog box.
Selection grid
Specifies whether you can edit or select the values. Values you
edit are written back to the electrical standards database file.
Edit or add records
Temporarily closes the dialog box so that you can select
an existing power feed load symbol and reuse its values.
Displays or sets the full load amps (FLA) value. The FLA value is
multiplied by the FLA Multiplier value to calculate the Maximum
load value.
FLA
Sets the multiplier factor. The FLA value is multiplied by this value
to calculate the Maximum load value.
FLA multiplier
Displays the calculated maximum load based on the product of
FLA and FLA multiplier.
Maximum load
NOTE The initial default values used for Voltage and the FLA multiplier are
controlled from the active OPT table in the electrical standards database file.
Wire Size Lookup
Specify the wire parameters and select a wire size from a list of wire sizes that
meet or exceed the parameters. Estimated energy losses per wire size can
provide valuable information in this selection.
Ribbon: Schematic tab Insert Components panel Circuit Builder
drop-down Circuit Builder.
Toolbar: Main Electrical
Menu: Components Circuit Builder
Command entry: AECIRCBUILDER
712 | Chapter 9 Circuits