2011

Table Of Contents
3 If any matching entries are found, the Special Annotation: Presets section
of the Circuit Selection dialog box, is enabled.
4 If you select Presets and click the Presets List button, the Annotation
Presets dialog box displays. The rows displaying the entries with non-blank
DEFAULT values are initially marked as Selected.
5 Edit the attribute values as necessary and click OK.
6 Select to Insert or Configure the circuit.
7 Circuit Builder processes each marker block on the circuit template. If
the CODE value matches the CODE value from the ANNO_CODE rows,
the attribute values marked as Selected in the Annotation Presets dialog
box are applied to the target attributes of the inserted component. If a
target attribute is not found, the value is inserted as an Xdata value.
Drawing templates
Each circuit starts with a main drawing template. These main circuit template
drawings are named ace_cb1*.dwg. Branching or nested circuit drawing
templates are named ace_cb2*.dwg. A branching circuit is a circuit inserted
as an option on to the main circuit, for example a control transformer circuit
or a power factor correction circuit.
The circuit drawing templates use the following naming convention.
ace_cb1_*.dwg - primary circuit drawing templates
ace_cb2_*.dwg - branching or nested circuit drawing templates
The default location for the circuit drawing templates is the schematic library
folder:
Windows XP: C:\Documents and Settings\All
Users\Documents\Autodesk\AcadE {version}\Libs\{library}\
Windows Vista, Windows 7: C:\Users\Public\Documents\Autodesk\AcadE
{version}\Libs\{library}\
One-line template drawings have a 1- suffix. The default location is in a
1- folder under the schematic library folder.
Windows XP: C:\Documents and Settings\All
Users\Documents\Autodesk\AcadE {version}\Libs\{library}\1-
Drawing templates | 659