2011

Table Of Contents
Optional command calls to perform the electrical standards database or
catalog lookups for the selected circuit element. This field controls the
right-hand side of the Circuit Configuration dialog.
LOOKUP_CMD
Optional catalog lookup table name. If the option contains multiple com-
ponents, such as a disconnect switch and a fuse, there are multiple columns
where n increments for each component.
TABLEn
The title for the component within the Setup & Annotation section on the
Configuration dialog box. If the option contains multiple components,
TITLEn
such as a disconnect switch and a fuse, there are multiple columns where
n increments for each component.
ANNO_CODE sheet
Allows you to predefine the description, installation, location, and other key
information for the motor or load and the individual components inserted
into the circuit.
Value is matched to the ANNO_CODE value from the ACE_CIRCS sheet.ANNO_CODE
Value is matched to the CODE value of the marker block on the circuit
template.
CODE
Attribute name on the component inserted at the position of the marker
block.
ATTRIBUTE
Text prompt displayed in the Annotation Presets dialog box.PROMPT
The default value for the attribute if annotation presets are
listed on page
708 or applied on page 706. This value can be a text value or an AutoLISP
expression that returns a text value.
DEFAULT
FutureOPTIONS
How Annotation Presets work
1 Make a selection from the Circuit Selection dialog box, for example
"Horizontal - FVNR - non reversing". This selection has a value in the
ANNO_CODE cell, "ANNO_3M".
2 Circuit Builder finds the group of entries that match up with code
"ANNO_3M" in the ANNO_CODE sheet of ace_circuit_builder.xls.
658 | Chapter 9 Circuits