2011

Table Of Contents
Indicates to display only modules in the .xhw file that
contains I/O addressing (PLCs). If a rack node only
Show only I/O modules
includes modules that are not PLC I/O modules, the
entire rack is removed from the tree structure. If a
rack node contains modules with and without I/O
addressing, the modules that do not have I/O ad-
dresses are removed.
Defines a terminal symbol to place into the spread-
sheet on the inner side of the in-line component
(between the I/O point and the in-line component).
Include inner terminals
All I/O addresses: Places the terminal symbol
name into the row of every I/O address listed in
the import spreadsheet.
I/O addresses defined: Places the terminal symbol
name into every row where an I/O point is
defined from Unity Pro. The defined address from
Unity Pro is the topographical address coming
from the I/O variable file that contains a value
for the address string.
Defines a terminal symbol to place into the spread-
sheet on the outer side of the in-line component
Include outer terminals
(between the I/O component and the wire connected
to the ladder rail).
All I/O addresses: Places the terminal symbol
name into the row of every I/O address listed in
the import spreadsheet.
I/O addresses defined: Places the terminal symbol
name into every row where an I/O point is
defined from Unity Pro. The defined address from
Unity Pro is the topographical address coming
from the I/O variable file that contains a value
for the address string.
I/O Variable File
Once you select a module node from the tree selection the data relative to the
I/O variable file displays for viewing and editing. The path and file name of
648 | Chapter 8 PLC