Indicate whether to include inner or outer terminals. Select whether
to place the terminal symbol names in every row or only the names
that have a defined I/O point.
In the Hardware File section, select the module to modify. The data
relative to the I/O variable file for the selected module displays in the
I/O Variable File section of the dialog box. If you select a module that
does not have addresses (such as power supplies or CPUs) the grid
remains empty.
Change the symbol name or device tag for any of the I/O points using
the right-click menu options. The Select Symbol option displays the
icon menu from which you can select the symbol name.
Specify the symbol name to insert for inner and outer terminals in
the spreadsheet. The default symbol name is HT0001 (a terminal that
maintains the wire number potential, has a tag strip ID and terminal
number, and is square). Click the Select from Icon Menu button to
select a terminal to use from the icon menu
9 Click OK.
10 Specify a file name and location for the PLC spreadsheet file and click
Save.
11 Specify a file name and location for the Equipment List file and click
Save.
12 To
create the PLC drawing on page 630 click Import/Export Data tab
Import panel PLC I/O Utility.
Unity Pro import
Prepares Unity Pro exported data for the Spreadsheet to PLC I/O utility.
Ribbon: Import/Export Data tab Import panel Unity Pro.
Toolbar: Insert PLC