Column 3 = ASSYCODE; column defined (left blank)
Column 4 = TAG; column defined (left blank)
Column 5 = LOC; column defined (left blank)
Column 6 = INST; column defined (left blank)
Column 7 = DESC1; partFamily variable from the .xhw file
Column 8 = WDBLKNAM; PLCIO
Import Unity Pro files to a spreadsheet
1 In Unity Pro, right-click the configuration file in the project browser and
select Export.
2 Enter a file name for the .xhw file and click Export.
3 Right-click the Variables & FB Instances file in the project browser and
select Export.
4 Enter a file name for the .xsy file and click Export.
NOTE We recommend that you export the files into the same location as
the AutoCAD project (.wdp) file.
If the export was successful, the Unity Pro command window states that
the file was exported with 0 errors or warnings.
5 Click Import/Export Data tab Import panel Unity Pro.
6 Select the Unity Pro hardware configuration file (.xhw) and click Open.
7 Select the Unity Pro I/O configuration file (.xsy) and click Open.
Upon successful validation of the files selected for import, the Unity Pro
Import dialog box displays.
8 In the Unity Pro Import dialog box, modify the selected files to create a
spreadsheet for PLC import. You can right-click on a module or rack in
the tree structure and select to include or exclude it from being saved
into the spreadsheet file. Do any of the following optional steps:
Indicate whether to display only modules in the .xhw file that contains
I/O addressing (PLCs).
Create PLC drawings from Unity Pro | 645