2011

Table Of Contents
Module Location: displays the location of the module in the rack
and is specified in the topoAddress of the .xhw file. (that is,
1.1\1.1)
Module Catalog Number: displays the catalog number of the
module and is specified in the partNumber element of the .xhw
file. (that is, 140CPS21400)
Unity Pro to AutoCAD Electrical Mapping File
The Unity Pro to AutoCAD Electrical mapping file, DEFAULT_UNITY.MAP,
allows you to define the text strings to be placed in the custom field of the
Unity Pro Data Editor to map directly to an AutoCAD Electrical schematic
symbol name.
AutoCAD Electrical Symbol Mapping File Example:
;This file is to be used for mapping of Unity Pro custom strings
;for PLC I/O devices to AutoCAD Electrical schematic symbol names
;Syntax: Value in Custom Field,Symbol Block File Name
;Example: PBNO,HPB11
; PBNC,HPB12
PB NC,HPB12
*2POS*,HSS112
*3POS*,HSS113
The comment fields (marked with ;) at the top of the file are used for
information. The custom field supports spaces in the string and wild cards.
NOTE The distance the remote component is located from the PLC and hot bus
rail is determined by the PLC settings file.
Equipment List Structure and Data
When you click OK on the Unity Pro Import dialog box, a PLC Spreadsheet
file is created along with an Equipment List spreadsheet file. The Equipment
List file includes all of the catalog information in the .xhw file. The structure
of the Equipment List is:
Column 1 = CATALOG; partNumber variable from the .xhw file
Column 2 = MANUFACTURER; found in Default_cat.mdb (PLCIO table)
644 | Chapter 8 PLC