2011

Table Of Contents
DescriptionCommand
haves as if it is an attribute tied to the compon-
ent block.
Displays all associated and parent components
to the selected component. A complete list of
Cross-Reference Check
AEXREFCHECK
components is extracted from the project
drawing set. The component's tag is read,
then all associated components are found and
listed in the dialog box. A bill of material check
can be performed to see if the item's descrip-
tion indicates that the quantity of contacts
can be accommodated.
Updates child and panel components with
installation, location, and description values
Child Location/Descrip-
tion Update
carried by the associated parent schematic
component.
AECHILDLOCUPDATE
Copies and/or adds cross-reference compon-
ent overrides from another symbol. You can
Copy/Add Component
Override
define components to have different cross-
referencing styles. The settings specified using
AECOPYOVERRIDE
this tool override the drawing properties.
Component overrides are copied when the
component is copied; similarly they are ap-
plied to multiple inserts of the same compon-
ent.
Removes the component overrides so the
cross-referencing commands use the settings
for the drawing or project.
Remove Component
Override
AERMOVERRIDE
Displays a cross-reference table for all stand-
alone PLC I/O points that carry the selected
component tag.
Cross-Reference Table
AESHOWXREFTABLE
Performs mass copies of location, installation,
group, or mount codes to all of the compon-
Copy Installation/Loca-
tion Code Values
ents you select. You either type in the desired
46 | Chapter 1 AutoCAD Electrical What's New