Table Of Contents
Ribbon: Import/Export Data tab Import panel PLC I/O Utility.
Toolbar: Insert PLC
Menu: Components Insert PLC Modules Spreadsheet to PLC I/O
Utility
Command entry: AESS2PLC
Select the spreadsheet output file and click Open. In the Spreadsheet to PLC
I/O Utility dialog box, click Setup.
NOTE New default values can be programmed into the source file. The program
source file name is "wdio.lsp." Open the file with any ASCII text editor and carefully
edit the values near the top of the file.
Ladder
Specifies the insertion point for first (or only) ladder on the
drawing. Corresponds to the upper left-hand corner of the
ladder.
Origin
Specifies to create a vertical bus ladder (with horizontal
wires) or horizontal bus ladder (with vertical wires).
Orientation
Specifies the default referencing system:Reference numbers
Numbers Only
Numbers Ruling
User Blocks
X-Y Grid: All referencing is tied to an X-Y grid system
of numbers and letters along the left-hand side and
top of the drawing. Set the vertical and horizontal index
numbers and letters, spacing, and origin in the X-Y
grid setup dialog box.
TIP Use negative spacing values for horizontal
or vertical to change the origin of the XY grid
system to be other than the upper left-hand
corner of the drawing.
636 | Chapter 8 PLC