2011

Table Of Contents
Specifies the total number of termination points on the PLC
module that receives the PLC address attributes.
Addressable Points
AutoCAD Block to insert
Specifies an AutoCAD block file to insert directly below the last I/O point
inserted parametrically. They are typically used for block files that represent
DIP switch settings and notes on how to configure the PLC module.
AutoLISP file to run at module insertion time
Specifies an AutoCAD Lisp routine to run after the program executes the
parametric build of the PLC module. They are typically used for inserting
groups of symbols and wires, or modifying attributes on symbols to
accommodate a more custom PLC module build.
Spreadsheet to PLC I/O Utility Insertion Position
Specifies the insertion position for this module when inserted during the
Spreadsheet to PLC I/O utility. Select from the list of options, Center, Left/Top,
or Right/Bottom.
Center - inserted centered between the bus lines of the ladder.
Left/Top - inserted near the left or top bus line of the ladder.
Right/Bottom - inserted near the right or bottom bus line of the ladder.
Module Box Dimensions
Opens a dialog box for defining the outer box dimensions of the module. The
box dimensions are calculated from the insertion point of the parametrically
built PLC symbols.
Module Prompts
Opens a dialog box for defining up to nine prompts to use at the time of
module insertion. You can specify the prompt number and the accompanying
text, or you can remove prompts from this dialog box.
Prompts at module insertion time
Defines up to nine prompts to use at the time of module insertion. You can
specify the prompt number and the accompanying text, or you can remove
prompts from this dialog box.
616 | Chapter 8 PLC