Prompt asks you at module insertion time for Octal, Decimal, and
Hexadecimal.
Specifies the power rating value for the PLC module.Rating
Specifies the total number of terminals defined on the PLC mod-
ule.
Terminals
NOTE It is not active since it is under the control of the total
number of terminals listed in the Terminal Type grid control.
Specifies the total number of termination points on the PLC
module that receives the PLC address attributes.
Addressable Points
AutoCAD Block to insert
Specifies an AutoCAD block file to insert directly below the last I/O point
inserted parametrically. They are typically used for block files that represent
DIP switch settings and notes on how to configure the PLC module.
AutoLISP file to run at module insertion time
Specifies an AutoCAD Lisp routine to run after the program executes the
parametric build of the PLC module. They are typically used for inserting
groups of symbols and wires, or modifying attributes on symbols to
accommodate a more custom PLC module build.
Module Box Dimensions
Opens a dialog box for defining the outer box dimensions of the module. The
box dimensions are calculated from the insertion point of the parametrically
built PLC symbols.
Module Prompts
Opens a dialog box for defining up to nine prompts to use at the time of
module insertion. You can specify the prompt number and the accompanying
text, or you can remove prompts from this dialog box.
Terminal block settings
Adds or updates the symbols available to build a module.
Overview of the PLC database file | 611