2011

Table Of Contents
Tag
Specifies a unique identifier assigned to each I/O point. The tag value can be
manually typed in the edit box.
Options
Substitutes a fixed text string for the %F part of the tag format. Retag
Component can then use this override format value to calculate a new tag for
the PLC module. For example, a certain PLC module must always have an
"IO" family tag value instead of "PLC" so that retag, for example, assigns IO-100
instead of PLC100. To achieve this tag override you would enter "IO-%N" for
the tag override format.
Line1/Line2
Specifies optional description text for the module. May be used to identify
the relative location of the module in the I/O assembly (example: Rack # and
Slot #).
Manufacturer
Lists the manufacturer number for the I/O point. Enter a value or select one
from the Catalog lookup.
Catalog
Lists the catalog number for the I/O point. Enter a value or select one from
the Catalog lookup.
Assembly
Lists the assembly code for the I/O point. The Assembly code is used to link
multiple part numbers together.
Catalog Lookup
Opens the Catalog Information dialog box.
Lists the manufacturer number for the component. Enter a value
or select one from the Catalog lookup.
Manufacturer
Lists the catalog number for the component. Enter a value or se-
lect one from the Catalog lookup.
Catalog
Insert PLC modules | 593