One-line symbols
A one-line symbol can be a parent, child, or terminal. These one-line symbols
use the same attributes as the schematic parent, child, and terminal symbols
but with the following exceptions.
DescriptionAttribute
The attribute must be present and carry a value of 1- to indicate it
is a one-line symbol, or 1-1 for the one-line bus-tap symbols. A
WDTYPE
bus-tap symbol is used to mark the beginning of a one-line circuit.
Schematic symbols do not carry this attribute or have the attribute
but with a blank value.
Omitted from one-line cable markers symbols since a one-line cable
marker can represent multiple conductors, multiple wires, or core
color assignments.
RATING1
Omitted from one-line terminal symbols since a one-line terminal can
represent multiple independent terminals.
TERM01
If a TERM01 attribute is added to a one-line symbol and carries a non-
blank value, it can be edited in the Insert/Edit Terminal Symbol dialog
box. However, terminal number text on one-line terminal symbols is
not linked back to terminal number assignments on schematic or
panel terminal representations.
NOTE Terminal Strip Editor does not process one-line terminals.
Hydraulic and P&ID symbols
DescriptionAttribute
Attribute for required component tag name (64 characters maximum).
The default value you assign becomes the family code character string
TAG1
AutoCAD Electrical uses to build the tag name of the component
when the block is inserted into your wiring diagram. This default
value character string is used as the Family Code (%F) portion of the
tag format code of the drawing you set up in the Drawing Properties
Components dialog box (example %F%N).
Optional attribute for component installation code (for example,
"MACH1"; 24 characters maximum).
INST
Optional attribute for component location code (for example, "FIELD";
"JBOX2"; 16 characters maximum).
LOC
326 | Chapter 5 Symbol Libraries