or attribute requirements, these libraries can be used as is. When AutoCAD
Electrical inserts such a block footprint symbol, it immediately becomes
AutoCAD Electrical smart.
Footprint block attribute/Xdata names
The following table is a list of footprint block data names that are inserted or
read by AutoCAD Electrical. If the footprint block has an attribute with any
name listed here, AutoCAD Electrical uses that attribute to carry the specific
piece of data. Otherwise, AutoCAD Electrical uses extended entity data with
names based on the data names listed here but with a VIA_WD_ prefix (ex:
"VIA_WD_DESC1").
identifies block as a component footprintFP
identifies block as a terminal footprintFPT
identifies block as a nameplateNP
panel component tag (used on component footprints and nameplates)P_TAG1
description line 1 - 3 (60 char max)DESC1-3
item/detail numberP_ITEM
optional attribute with a value of 1 indicates the item number is fixedITEM_FLAG
manufacturer name (24 char max)MFG
catalog number (60 char max)CAT
optional assembly codeASSYCODE
installation code (24 char max)INST
location code (16 char max)LOC
mount location code (24 char max)MOUNT
group location code (24 char max)GROUPWITH
schematic symbol block name (used for catalog lookup)WDBLKNAM
rating values (60 char max each)RATING1-12