2011

Table Of Contents
if the leader itself overlays another object). Select the method for
inserting new wire numbers as leaders: As Required, Always, or
Never.
NOTE This change does not affect wire numbers that are already
present on the drawing.
Wire Type
Displays the Rename User Columns dialog box used for renaming User1 to
User20 header columns in the Set Wire Type, Create/Edit Wire Type, and
Change/Convert Wire Type dialog boxes.
Project properties: cross-references tab
Modify your project default settings for cross-referencing. Any new drawing
files created within the project are saved with the project default settings for
cross-referencing.
Ribbon: Project tab Project Tools panel Manager.
Toolbar: Main Electrical 2
Menu: Projects Project Project Manager
Command entry: AEPROJECT
In the Project Manager, right-click the project name, and select Properties.
Select the Cross-References tab.
Cross-reference Format
Defines the cross-reference annotation format. One replaceable parameter,
%N, must always be part of the cross-reference format string. A typical format
string might be the %N parameter. Use Same Drawing for on-drawing
references and Between Drawings for off-drawing references. You can use the
same format for both.
NOTE AutoCAD Electrical provides some predefined formats for you to use or you
can enter your own format using
replaceable parameters on page 236.
Overview of project and drawing properties | 215