Table Of Contents
ample, tag "K101" becomes "-K101" but "+LOC1-
K101" remains unchanged._
NOTE This suppression takes place automatically in
reports; and takes place graphically only when a
component is inserted, edited, or retagged.
Specifies to exclude the Installation and Location
code values as part of the tag when displaying. For
Format Installation/Location into tag
example, if it is not on, a tag might show up as K16
in the Surf dialog box, but if selected the tag might
show up +AAA-K16 (where AAA is the location).
Suppresses Location and Installation values on com-
ponents if they match the drawing default values.
Suppress Installation/Location in tag when
match drawing default
NOTE Update cross-reference text using the Auto-
CAD Electrical Cross-reference command.
Specifies to exclude Installation and Location values
as part of the tag when displayed in reports.
Suppress Installation/Location in tag on
reports
Fills the Installation and Location edit boxes on the
Insert/Edit component dialog box. The attributes on
Upon insert: automatic fill Installation/Loc-
ation with drawing default or last used
the block with drawing default or last used values (if
no drawing default).If not selected, these edit boxes
and attributes are not filled in and are assumed.
NOTE Avoid using a mixture of drawings in the project when using the Combine
Installation/Location Tag mode. For example, do not include some drawings with
drawing-wide Installation or Location values and some without drawing-wide
values. It can result in a disruption of the child and parent component relationship
under certain circumstances.
Component Options
Forces description text to upper case.Description text upper case
Launches the Item Numbering Setup dialog box. The
dialog box contains options for project or drawing
Item Numbering
wide item numbering, and per-part number or per-
component item numbering.
210 | Chapter 4 Drawing and Project Properties