2011

Table Of Contents
Project settings
1 Click Project tab Project Tools panel Manager.
2 Right-click on the project name in Project Manager.
3 Select Properties.
4 Select the Project Settings tab.
5 Expand the Schematic Libraries section.
6 Remove any folder names you no longer want and add any that you
need. For example, remove the JIC folder and add the IEC library folder.
NOTE AutoCAD Electrical searches for a symbol in the order the folders are
listed.
7 Expand the Schematic Icon Menu File section.
8 Remove the menu you do not want and add the menu you need. For
example, remove the ACE_JIC_MENU.DAT file and add the
ACE_IEC_MENU.DAT file.
9 Click OK.
Drawing settings - change as a project setting
Component tagging options can be changed as a project setting and applied
to a group of drawings.
1 Click Project tab Project Tools panel Manager.
2 Right-click on the project name in Project Manager.
3 Select Properties.
4 Select the Components tab.
5 In the Component TAG Options section, check the Combined
Installation/Location tag mode option for IEC tagging, uncheck it for JIC
tagging.
If using IEC tagging, set any of the other tagging options.
2126 | Chapter 24 Advanced Productivity