2011

Table Of Contents
Cross-reference Tab
(nontable) format, you can define details of the
graphical format by clicking Setup.
Styles Tab
In IEC, it is sometimes preferable to display wire
connections as tee markers instead of connection
Wire Style
dots. To do this, in the Wire Tee section, select the
appropriate angle tee marker from the list.
Drawing Format Tab
In IEC, the most common ladder orientation is Ho-
rizontal. In the Ladder Defaults section, configure
how to display your horizontal ladders.
Ladder Defaults
Defines the type of referencing that is used to re-
place the %N value for component tag and wire
Format Referencing
number formats. In IEC, the most commonly used
format is X Zones.
NOTE If you want AutoCAD Electrical to place the
labels for the X-Y Grid or X Zones referencing style,
use the appropriate command from the Insert
Ladder toolbar.
X-Y Grid: All referencing is tied to an X-Y grid
system of numbers and letters along the left-
hand side and top of the drawing.Set your
drawing's vertical and horizontal index numbers
and letters, spacing, and origin in the X-Y grid
setup dialog box.
TIP Use negative spacing values for Hori-
zontal or Vertical if you want to change
the X-Y grid system's origin to be other
than the upper left-hand corner of the
drawing
X Zones: Similar to X-Y Grid, but there is not a
Y-axis. Set your drawing's horizontal labels,
Configure projects for various drawing standards | 2123