Windows XP: C:\Documents and Settings\All
Users\Documents\Autodesk\Acade {version}\jic125
Windows Vista, Windows 7: C:\Users\Public\Documents\Autodesk\Acade
{version}\jic125
4 In the Attribute template section, choose Symbol: Horizontal Terminal.
5 In the Attribute template section, choose Type: Terminal with wire
number.
6 In the Select from drawing section:, click Select objects and select the
rectangle.
7 Select OK.
Add attributes
In this part of the exercise, you insert some AutoCAD Electrical attributes from
the Symbol Builder Attribute Editor. You are not limited to these attributes,
and you can include your own user-defined attributes on the AutoCAD
Electrical block files.
NOTE The TAGSTRIP attribute is the only one required for a schematic terminal.
The other attributes in the Required section are expected on a schematic terminal,
however the symbol is recognized as a schematic terminal without them.
1 If the Symbol Builder Attribute Editor is not visible,
Click Symbol Builder tab Edit panel Palette Visibility Toggle.
2 Select the TAGSTRIP attribute.
3
Select the Properties tool to launch the Insert/Edit Attributes dialog
box.
4 Change the height to 0.125 and Justify to Center.
5 Select OK.
6 Click the Insert Attribute tool.
Build your own symbols | 2091