2011

Table Of Contents
The elements in the first sublist of the "#data" list are held in memory in the
following order. The values related to the motor are held in the first eight
elements. See the API documentation for a complete list of elements.
0 Motor Type
1 Power
2 Units
3 Voltage
4 Phase
5 Hertz (Hz)
6 Speed (RPM)
7 Full Load Amps (FLA)
NOTE Circuit Builder numbers this indexed list starting at 0 rather than 1.
There are two ways to map these values to the attributes on a component.
On the marker block for the motor, fuse, or circuit breaker symbol in the
circuit template drawing.
In the Circuit Builder spreadsheet circuit codes sheet.
NOTE The attribute value defined on the marker block overrides any value defined
in the spreadsheet.
Marker block method
1 Open the circuit template drawing that contains the marker block for
the motor, fuse, or circuit breaker symbol.
2 Find the correct marker block for the symbol.
3 Edit its MISC1 attribute value using the format {attribute name}=@#@.
Replace the # with the appropriate index digit to map the correct
element. For example, to map the horsepower to the RATING2 attribute,
enter "RATING2=HP: @1@". To also map the full load amp value to the
RATING4 attribute, enter "RATING2=HP: @1@;RATING4=Full load: @7@
amps". Remember, the indexed list of values is zero based.