2011

Table Of Contents
5 Open the 3ph_H worksheet.
6 Find the entry for Control transformer and circuit - non-reversing in the
COMMENTS column.
7 Find the CODE value for this row, XF01.
This CODE value links the marker block to the circuit code sheet.
8 Switch back to the drawing and locate the marker block with the CODE
value of XF01.
9 Erase the marker block using the AutoCAD ERASE command.
10 Repeat the steps to locate and delete the power factor correction marker
block, CODE=KVAR1.
Add a marker block
You can add a marker block by inserting the library symbol,
ace_cb_marker_block.dwg, or by copying an existing marker block and
modifying the attribute values. In this section, you will insert a marker block
that directs Circuit Builder to display a list of possible components to insert
in the Circuit Configuration dialog box.
NOTE This exercise demonstrates the capabilities of Circuit Builder and the result
may not necessarily be electrically valid.
1 Determine exactly where in the template you want this specific
component inserted as the circuit is built.
2 Enter INSERT at the command line to launch the AutoCAD block insert
command.
3 Browse to ace_cb_marker_block.dwg and insert this block at the desired
location.
A copy of this block is installed in each of the schematic library folders,
JIC125, IEC2, and so on.
NOTE You could also use the AutoCAD COPY command and copy a nearby
marker block into the desired location.
4 Enter ATTEDIT and select the marker block.
5 Enter a value for the CODE attribute, for example USR001.
2036 | Chapter 24 Advanced Productivity