2011

Table Of Contents
MISC1 = _WIRESKIP=2;_MAXTRAPCOUNT=200 - defines any special
handling of the marker block. See the
Marker block attributes on page
660 topic for a complete list of supported values.
3 Change the MISC1 value to _MAXTRAPCOUNT=200, removing
_WIRESKIP=2.
The _WIRESKIP value defines the number of wires to skip over when
trying to connect to the vertical bus when inserted. Removing this value
directs Circuit Builder to connect to the first vertical wire it finds.
The _MAXTRAPCOUNT limits the relative distance that circuit builder
searches to find a wire to connect to. It is measured in an integer number
of wire connection
trap on page 232 distance units. If _MAXTRAPCOUNT
is not defined or is zero, the search is across the whole extents of the
drawing.
4 Click OK.
5 Enter ATTEDIT and select the bottom WCON marker block.
6 Change the MISC1 value to _WIRESKIP=2;_MAXTRAPCOUNT=200, making
sure to enter the semi-colon character between the values.
It tells Circuit Builder to skip over two vertical wires when trying to
connect to the vertical bus and to search up to 200 times the trap distance
for a vertical wire to connect to. If none are found within that distance,
Circuit Builder will not stretch this wire.
7 Click OK.
Remove unnecessary marker blocks
The copied circuit has marker blocks for a control transformer and power
factor correction capacitor. For this custom circuit, these options are not
needed and the marker blocks can be removed.
1 To verify which marker block is for the control transformer, switch over
to ace_circuit_builder.xls.
2 Open the ACE_CIRCS worksheet.
Find which circuit codes sheet is used for the original template you copied
over, ace_cb1_FVNR_H.dwg.
3 Locate a row with the name of the original template you copied over,
ace_cb1_FVNR_H.dwg, in the DWG_TEMPLATE field.
4 Find the SHEET_NAME value for this row, 3ph_H.
Add a new circuit | 2035