Location code: MACHINE
Click OK.
9 In the Keep dialog box, select:
Keep this one
Show edit dialog box after each
Click OK
10 In the Insert/Edit Component dialog box, specify:
Component Tag: LS522
Description: Line 1: PALLET LEAVING
Description: Line 2: STATION
Location code: MACHINE
Click OK.
The normally open limit switches are inserted into the drawing.
Annotating PLC I/O descriptions
You can add description text to a PLC module using the Edit Component tool.
You can change the descriptions at any time. However, edit each split PLC
piece separately.
Add description text
1 Click Schematic tab Edit Components panel Edit Components
drop-down Edit.
2 Respond to the prompts as follows:
Select component/cable/location box to EDIT:
1816 | Chapter 23 Tutorials