2011

Table Of Contents
Swap switches while keeping wire connections
1 If AEGS is not the active project, in the Project Manager, right-click AEGS
and select Activate.
2 In the Project Manager, double-click AEGS to expand the drawing list.
3 In the Project Manager, Project Drawing List, double-click AEGS04.dwg.
4 Zoom in on the limit switch on line reference 406.
5 Click Schematic tab Edit Components panel Swap/Update Block.
6 In the Swap Block/ Update Block/ Library Swap dialog box, specify:
Option A: Swap a Block - drawing wide
Pick new block from icon menu
Retain old block scale
Auto re tag if parent swap causes FAMILY change
Attribute Mapping: Use Same Attribute Names (default)
Click OK.
7 In the Insert Component: JIC Schematic Symbols dialog box, click
Miscellaneous Switches.
8 In the JIC: Other Switch Types dialog box, click Proximity Switch NO.
9 Respond to the prompts as follows:
Select component type to swap out: Select the limit switch, LS406
1808 | Chapter 23 Tutorials