It directs Circuit Builder to use the tags from the one-line circuit for the
components with matching marker block code values.
14 Select Configure.
15 Select an insertion point on the bus for the new circuit.
16 Verify that the same circuit elements as the referenced one-line motor
circuit are selected. The default options are based on the referenced circuit.
SelectCircuit Elements
Motor: 3ph motorMotor symbol
Ground/PE wire connection: No
Main Disconnect: Disconnect switch and FusesDisconnecting means
Include N.O. Auxiliary contact: No
Include control circuit: NoneControl transformer and circuit - non-re-
versing