3 Click Yes to apply the project default values to the drawing settings.
4 Click Schematic tab Insert Wires/Wire Numbers panel Insert Ladder
drop-down Insert Ladder.
5 Insert a 3-phase ladder.
6 Click Schematic tab Insert Components panel Circuit Builder
drop-down Circuit Builder.
7 The Circuit Selection dialog box displays.
8 Select 3ph Motor Circuit: Horizontal - FVNR - non reversing.
9 Select Reference Existing Circuit.
10 Select the List button.
The Existing Circuits dialog box displays.
11 Select the one-line motor control circuit inserted on One-Line.dwg, MOT1.
12 Click OK.
The CODE and UI_VAL values from the circuit codes sheet of the circuit
builder spreadsheet control the default circuit element options. For
example, the one-line circuit used the Disconnect switch and fuses option
with a UI_VAL of 4. When the 3-phase circuit references this one-line
circuit, the disconnecting means option with a UI_VAL of 4 becomes
the default. If a matching UI_VAL is not found for a particular marker
block CODE value, the default as defined by the X in the UI_DEF
column is used.
When the new circuit is built, component values from the referenced
circuit are applied to components in the new circuit only if the
marker
block
on page 659 code matches.
13 Turn off the Retag new components check box.