2011

Table Of Contents
Title Block Setup - WD_TB attribute method
An invisible attribute on a title block of the drawing, named "WD_TB," is
encoded with the mapping information. This method eliminates the need for
an external mapping text file.
1 Click Project tab Project Tools panel Manager.
2 If AEGS is not the active project, activate the AEGS project.
If AEGS is in the list of open projects:
Select AEGS and right-click.
Click Activate.
If AEGS is not in the list of open projects:
Select the project list drop-down.
Click Open Project.
On the Select Project File dialog box, navigate to and select the
AEGS.WDP file.
Click Open.
3 Open the title block base drawing created previously, ACADE_TITLE.DWG,
that contains the attribute definition objects.
4 Click Project tab Other Tools panel Title Block Setup.
5 Select the title block link method: Method 2: WD_TB attrib.
6 Click OK.
Title Block Setup reads the attribute definitions. The Title Block Setup
dialog box displays. Each drop-down list contains all the attribute
definition objects found on the drawing.
1714 | Chapter 23 Tutorials